EXTERIOR SHEETING

Heavy-Duty Metal Sheeting – 26GA Standard / 24GA Upgrade
PBR PANEL (STANDARD FOR MOST BUILDINGS)

PBR PANEL (STANDARD FOR MOST BUILDINGS)

Coverage Width: 36"

Minimum Slope: 1/2:12

Panel Attachment: Exposed Fastening System

Gauge: 26 (standard); 24, 22 (optional)

Finishes: Smooth (standard); Embossed (optional)

Coatings: Galvalume Plus®, Signature® 200, Signature® 300

Rib Spacing: 12" on center

Rib Height: 1-1/4"

Length: 5'-0" to 50'-0"

PBU PANEL

PBU PANEL

Coverage Width: 32"

Minimum Slope: 3:12

Panel Attachment: Exposed Fastening System

Gauge: 26 (standard); 24, 22 (optional)

Finishes: Smooth (standard); Embossed (optional)

Coatings: Galvalume Plus®, Signature® 200, Signature® 300

Rib Spacing: 2 2/3" on center

Rib Height: 5/8"

Length: 5'-0" to 50'-0"

PBC PANEL

PBC PANEL

Coverage Width: 32"

Minimum Slope: 3:12

Panel Attachment: Exposed Fastening System

Gauge: 26 (standard); 24, 22 (optional)

Finishes: Smooth (standard); Embossed (optional)

Coatings: Galvalume Plus®, Signature® 200, Signature® 300

Rib Spacing: 2 2/3" on center

Rib Height: 7/8"

Length: 5'-0" to 50'-0"

PBD PANEL

PBD PANEL

Coverage Width: 32"

Minimum Slope: 3:12

Panel Attachment: Exposed Fastening System

Gauge: 26 (standard); 24, 22 (optional)

Finishes: Smooth (standard); Embossed (optional)

Coatings: Galvalume Plus®, Signature® 200, Signature® 300

Rib Spacing: 2 2/3" on center

Rib Height: 5/8"

Length: 5'-0" to 50'-0"

7.2 PANEL

7.2 PANEL

Coverage Width: 36"

Minimum Slope: 1/2:12

Panel Attachment : Exposed Fastening System

Gauge: 24 (standard); 26, 22 (optional)

Finishes: Smooth (standard); Embossed (optional)

Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic

Rib Spacing: 7.2" on center

Rib Height: 1-1/2"

Length: 5'-0" to 50'-0"

ULTRA-DEK STANDING SEAM (SNAP TOGETHER)

ULTRA-DEK STANDING SEAM (SNAP TOGETHER)

Coverage Width: 18", 24"

Minimum Slope: 1/4:12

Panel Attachment: Concealed Fastening System; Low, High (fixed or sliding)

Gauge: 24 (standard); 22 (optional)

Finishes: Smooth (standard); Embossed (optional)

Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic

SUPERLOK STANDING SEAM (MECHANICALLY FIELD SEAMED)

SUPERLOK STANDING SEAM (MECHANICALLY FIELD SEAMED)

Coverage Width: 12", 16"

Minimum Slope: 1/2:12

Panel Attachment: Concealed Fastening System; Low, High (fixed or floating), Utility (no insulation clearance)

Gauge: 24 (standard); 26, 22 (optional)

Finishes: Striated (standard); Embossed Striated (optional)

Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic

LOKSEAM STANDING SEAM (SNAP TOGETHER)

LOKSEAM STANDING SEAM (SNAP TOGETHER)

Coverage Width: 12", 16", 18"

Minimum Slope - 3:12

Panel Attachment: Concealed Fastening System, Standard and UL90 Clips

Gauge:24 (standard);26 (12") 22 (12", 16", 18") (optional)

Finishes: Striated (standard); Embossed Striated (optional)

Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic

DOUBLE-LOK STANDING SEAM (MECHANICALLY FIELD SEAMED)

DOUBLE-LOK STANDING SEAM (MECHANICALLY FIELD SEAMED)

Coverage Width: 18", 24"

Minimum Slope: 1/4:12

Panel Attachment: Concealed Fastening System; Low, High and 2" Stand Off Sliding Clips

Gauge: 22 and 24

Finishes: Smooth (standard); Embossed (optional)

Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic

BATTEN-LOK HS STANDING SEAM (MECHANICALLY FIELD SEAMED)

BATTEN-LOK HS STANDING SEAM (MECHANICALLY FIELD SEAMED)

Coverage Width: 12", 16"

Minimum Slope: ½:12

Panel Attachment: Concealed Fastening System; Low, High (fixed or floating), Utility (no insulation clearance)

Gauge: 24 (standard); 22 (optional)

Finishes: Smooth or Embossed; with Striations or Striations and Pencil Ribs

Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic