EXTERIOR SHEETING
Heavy-Duty Metal Sheeting – 26GA Standard / 24GA Upgrade
PBR PANEL (STANDARD FOR MOST BUILDINGS)
Coverage Width: 36"
Minimum Slope: 1/2:12
Panel Attachment: Exposed Fastening System
Gauge: 26 (standard); 24, 22 (optional)
Finishes: Smooth (standard); Embossed (optional)
Coatings: Galvalume Plus®, Signature® 200, Signature® 300
Rib Spacing: 12" on center
Rib Height: 1-1/4"
Length: 5'-0" to 50'-0"
PBU PANEL
Coverage Width: 32"
Minimum Slope: 3:12
Panel Attachment: Exposed Fastening System
Gauge: 26 (standard); 24, 22 (optional)
Finishes: Smooth (standard); Embossed (optional)
Coatings: Galvalume Plus®, Signature® 200, Signature® 300
Rib Spacing: 2 2/3" on center
Rib Height: 5/8"
Length: 5'-0" to 50'-0"
PBC PANEL
Coverage Width: 32"
Minimum Slope: 3:12
Panel Attachment: Exposed Fastening System
Gauge: 26 (standard); 24, 22 (optional)
Finishes: Smooth (standard); Embossed (optional)
Coatings: Galvalume Plus®, Signature® 200, Signature® 300
Rib Spacing: 2 2/3" on center
Rib Height: 7/8"
Length: 5'-0" to 50'-0"
PBD PANEL
Coverage Width: 32"
Minimum Slope: 3:12
Panel Attachment: Exposed Fastening System
Gauge: 26 (standard); 24, 22 (optional)
Finishes: Smooth (standard); Embossed (optional)
Coatings: Galvalume Plus®, Signature® 200, Signature® 300
Rib Spacing: 2 2/3" on center
Rib Height: 5/8"
Length: 5'-0" to 50'-0"
7.2 PANEL
Coverage Width: 36"
Minimum Slope: 1/2:12
Panel Attachment : Exposed Fastening System
Gauge: 24 (standard); 26, 22 (optional)
Finishes: Smooth (standard); Embossed (optional)
Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic
Rib Spacing: 7.2" on center
Rib Height: 1-1/2"
Length: 5'-0" to 50'-0"
ULTRA-DEK STANDING SEAM (SNAP TOGETHER)
Coverage Width: 18", 24"
Minimum Slope: 1/4:12
Panel Attachment: Concealed Fastening System; Low, High (fixed or sliding)
Gauge: 24 (standard); 22 (optional)
Finishes: Smooth (standard); Embossed (optional)
Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic
SUPERLOK STANDING SEAM (MECHANICALLY FIELD SEAMED)
Coverage Width: 12", 16"
Minimum Slope: 1/2:12
Panel Attachment: Concealed Fastening System; Low, High (fixed or floating), Utility (no insulation clearance)
Gauge: 24 (standard); 26, 22 (optional)
Finishes: Striated (standard); Embossed Striated (optional)
Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic
LOKSEAM STANDING SEAM (SNAP TOGETHER)
Coverage Width: 12", 16", 18"
Minimum Slope - 3:12
Panel Attachment: Concealed Fastening System, Standard and UL90 Clips
Gauge:24 (standard);26 (12") 22 (12", 16", 18") (optional)
Finishes: Striated (standard); Embossed Striated (optional)
Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic
DOUBLE-LOK STANDING SEAM (MECHANICALLY FIELD SEAMED)
Coverage Width: 18", 24"
Minimum Slope: 1/4:12
Panel Attachment: Concealed Fastening System; Low, High and 2" Stand Off Sliding Clips
Gauge: 22 and 24
Finishes: Smooth (standard); Embossed (optional)
Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic
BATTEN-LOK HS STANDING SEAM (MECHANICALLY FIELD SEAMED)
Coverage Width: 12", 16"
Minimum Slope: ½:12
Panel Attachment: Concealed Fastening System; Low, High (fixed or floating), Utility (no insulation clearance)
Gauge: 24 (standard); 22 (optional)
Finishes: Smooth or Embossed; with Striations or Striations and Pencil Ribs
Coatings: Galvalume Plus®, Signature® 200, Signature® 300, Signature® 300 Metallic